WeatherNext 3 exposes dew point at two different scales: a 0.05 degree station head for 2 m conditions and a 0.1 degree gridded surface field. Relative humidity is usually derived from those values, not read as a separate model variable. This independent guide explains the difference and how to use the pair without over-reading a single percentage. For the temperature workflow, see the temperature guide. Updated November 26, 2026 by the WeatherNext 3 Editorial Team.
Humidity affects comfort, fog, dew, crop stress and cooling demand, but local terrain and station exposure can change the value inside a single grid cell.

The model exposes dew point directly; relative humidity and comfort indices are derived downstream.
Station-head dew point resolution, roughly 5 km.
Gridded surface dew point resolution, roughly 10 km.
Documented native timestep for the surface fields.
Humidity guide
Yes, through dew point and related surface fields. The useful question is which field and which spatial head you are reading.

WeatherNext 3 models moisture as part of its atmospheric state. In the public surface variable list, the directly named humidity field is dew point: dewpoint_temperature_2m on the 0.1 degree gridded surface, and station_head_dewpoint_temperature_2m on the 0.05 degree station head. Both are in kelvin.
Dew point is an absolute measure of moisture. It tells you the temperature to which air must cool for saturation to occur. Relative humidity is a ratio that changes with temperature. The same dew point can feel humid on a cool morning and much less humid on a hot afternoon.
That is why a forecast page should show both if humidity is part of the decision. A relative-humidity percentage without temperature is hard to interpret. A dew point with temperature, wind and cloud cover is a more useful physical description of the air mass.
Use station_head_dewpoint_temperature_2m when your question is tied to a station-like land point and you want the highest documented surface resolution. Use dewpoint_temperature_2m when you need a consistent gridded field across a region or when you are joining dew point to the other 0.1 degree surface variables.
Do not assume the station head is automatically better for every point. It is trained for station-like conditions and has a 0.05 degree grid; a gridded field may be more coherent for a regional map. Compare both against a nearby observation when the decision is local.
The model gives you temperature and dew point in kelvin. Convert both to Celsius, then use a Magnus-type approximation. This is a downstream calculation, not a replacement for a verified humidity product.
import math
def relative_humidity_percent(temperature_c: float, dewpoint_c: float) -> float:
# Magnus approximation; suitable for a quick derived display.
a, b = 17.625, 243.04
gamma_t = (a * temperature_c) / (b + temperature_c)
gamma_td = (a * dewpoint_c) / (b + dewpoint_c)
return 100.0 * math.exp(gamma_td - gamma_t)
t_c = 22.0
td_c = 16.0
print(round(relative_humidity_percent(t_c, td_c), 1))
If the dew point exceeds the temperature, the input pair is inconsistent or one field has a local bias. Treat that as a data-quality signal rather than forcing the result into a clean percentage. Apply the same check before calculating heat index, fog likelihood or dew-formation risk.
Humidity is strongly affected by local surface conditions. A coastal breeze, an irrigated field, a valley cold pool, a city heat island and a mountain slope can produce different moisture and temperature within one 5 or 10 km cell. Fog can form in a low-lying pocket while the grid cell average remains above saturation.
Use the hourly sequence to see the direction of change. A dew point that is nearly steady while temperature falls toward it is a useful signal for overnight condensation or fog. A large temperature-dew-point spread that closes quickly after sunset deserves more attention than a single mid-day relative-humidity number.
The station head can show artifacts and per-sample bias, and the documented limitations apply to station and precipitation outputs in particular. A single ensemble member is not a clean local observation. Use the ensemble statistics, compare with nearby stations and keep official warnings authoritative when fog, heat or severe weather affects safety.
For agriculture, energy and building operations, define a threshold in physical units and validate it locally. “Humidity above 80%” is not a portable decision rule if the underlying temperature, sensor exposure and time window are unspecified.
Dew point, relative humidity and the limits of a local humidity forecast.
Next: temperature, precipitation or ensemble uncertainty.
Inspect temperature, dew point, wind and precipitation together for the next hourly window. Seven-day free trial, cancel anytime. Related: the forecast guide and the complete guide.